3.1

Nickel Layer Requirements / 镍层要求

第12页

第1-40行

Electroless nickel thickness: minimum 3.0 um, maximum 6.0 um measured by XRF per IPC-TM-650 2.3.28. Nickel phosphorus content: 7-11 percent by weight for optimal solderability and wire bondability. Nickel deposit uniformity: thickness variation across panel shall not exceed plus or minus 15 percent of target value. Nickel surface morphology: smooth, uniform deposit free of pits, nodules, and skip plating. Bath chemistry control: pH maintained at 4.5-5.0, temperature at 85-90C, nickel concentration per bath supplier specification. Pre-treatment: microetch depth 0.5-1.5 um before nickel deposition to ensure adhesion. Adhesion test: tape test per IPC-TM-650 2.4.28 with no nickel lifting after 3 cycles.

nickelthicknessXRFphosphorusadhesionmicroetch
3.3

Gold Layer Requirements / 金层要求

第18页

第1-35行

Immersion gold thickness: minimum 0.05 um (50 nm), typical range 0.05-0.10 um. Gold thickness measurement by XRF with nickel underlayer correction factor applied. Gold coverage: complete coverage of nickel surface required; bare nickel exposure is a defect. Gold color: uniform yellow appearance; dark or discolored areas indicate process issues. Immersion time: controlled dwell time in gold bath, typically 10-20 minutes depending on target thickness. Gold bath contamination limits: copper less than 5 ppm, nickel less than 10 ppm, iron less than 3 ppm. Post-gold rinse: DI water rinse followed by hot air dry to prevent staining.

goldimmersionthicknessXRFcoveragecontamination
4.2

Black Pad Prevention Testing / 黑垫预防测试

第24页

第1-42行

Black pad defect characterization: brittle fracture at nickel-gold interface caused by excessive nickel corrosion during gold immersion. Prevention measures: control gold bath pH above 4.5, limit immersion time, maintain proper nickel bath chemistry. Test method: cross-section analysis of ENIG pads after thermal aging at 150C for 4 hours. Acceptance criteria: no interfacial fracture or void formation at Ni-Au interface under 200x magnification. Wire bond test: gold wire bond pull strength minimum 5 grams force for 25 um wire on aged samples. Solder joint shear test: minimum shear strength per JESD22-B116 after multiple reflow cycles. Nano-indentation: optional advanced test to measure interfacial brittleness quantitatively.

black padnickelgoldinterfacewire bondshearbrittle
5.1

Solderability Requirements / 可焊性要求

第32页

第1-38行

Solderability test per IPC-J-STD-003 Category 2 wetting balance method. Wetting time: maximum 2 seconds at 245C with ROL0 flux. Meniscus rise: minimum 95 percent coverage on test coupon. Steam aging preconditioning: 8 hours steam aging to simulate 6-month shelf life before testing. Multiple reflow tolerance: ENIG finish shall maintain solderability through minimum 3 reflow cycles at 260C peak. Contact resistance: maximum 10 milliohm per pad measured by four-point probe method. Flux compatibility: verified with both water-soluble and no-clean flux chemistries. Shelf life: minimum 12 months when stored in original packaging at controlled humidity below 60 percent RH.

solderabilitywettingsteam agingreflowcontact resistanceshelf life
6.1

Lead-Free Assembly Compatibility / 无铅组装兼容性

第40页

第1-38行

ENIG finish shall withstand lead-free reflow peak temperature of 260C for minimum 3 cycles without degradation. Nickel-gold intermetallic formation: AuSn4 and Ni3Sn4 phases characterized by SEM-EDS after reflow. Intermetallic layer thickness: total IMC shall not exceed 3 um after 3 reflow cycles. Pad cratering resistance: ENIG pads shall pass BGA pad cratering test per IPC-TM-650 2.4.37. Thermal shock resistance: no cracking or delamination after 1000 thermal cycles from -40C to +125C. Tin whisker evaluation: ENIG finish inherently resistant to tin whisker growth; no whisker mitigation plan required. RoHS compliance: ENIG process chemicals shall be free of restricted substances per EU RoHS 2011/65/EU.